6.3 Site coverage in commercial buildings

The permissible site coverage in a commercial building shall be within set back rules. Cantilevered projection in commercial buildings shall be allowed only at the rear side.

6.3.1 FRONT SET BACK
A minimum front set back of 1.5 m shall be maintained from the property line or follow existing building lines.

6.3.2 SIDE SET BACK
A minimum set back of 2 m shall be maintained on either side. No cantilever and balconies shall be allowed at the sides. A combined building proposed on two or more adjoining plots may be permitted, on the condition that a set back of at least 50% of the savings is added on the sides.

6.3.3 REAR OR OTHER SET BACK
(a) The rear set back shall be not less than 5 m at all points in areas not connected by sewer lines.
(b) The rear set back in areas connected with sewer lines shall be at least 3 m at all points.