7.3 Circulation space requirements


    DIMENSIONS FOR:
    RESIDENTIAL BUILDINGS INSTITUTIONAL AND COMMERCIAL BUILDINGS
7.3.1 Clear width of private corridor or staircase (internal stair serving one residence only) Min 900mm N/A
7.3.2 Clear width of common corridor or staircase Min 1100mm Min 1500mm

(unless calculated to be greater according to fire escape rules)
7.3.3 Height of staircase handrail above pitch line of staircase Min 900mm Min 900mm
7.3.4 Staircase riser Max 190mm Max 190mm
7.3.5 Staircase tread Min 250mm Min 280mm
7.3.6 Height of doors Min 1800mm Min 2000mm
7.3.7 Width of door to habitable room Min 850mm Min 900mm
7.3.8 Width of door to main entrance Min 900mm Min 1000mm
7.3.9 Width of other doors Min 700mm Min 850mm
7.3.10 Habitable room floor to ceiling height in high altitude Min 2450mm Min 2450mm
7.3.11 Habitable room floor to ceiling height in low altitude Min 2750mm Min 2750mm
7.3.12 Water closet, bathroom or store floor to ceiling height Min 2100mm Min 2300mm
7.3.13 Mezzanine floor to ceiling height Min 2100mm Min 2300mm